EATON MTL4575 TEMPERATURE CONVERTER THC or RTD input + Alarm
search
  • EATON MTL4575 TEMPERATURE CONVERTER THC or RTD input + Alarm
  • EATON MTL4575 TEMPERATURE CONVERTER THC or RTD input + Alarm

EATON MTL4575 TEMPERATURE CONVERTER THC or RTD input + Alarm

$140.00
264697015315
Quantity
In Stock

 

We provide 6-month warranty for all used products. Before shipping all products carefully tested and packed in hard box with bubble wrap. If you pay with PayPal you can use buyer protection program.

 

For shipping we use EMS express post (delivery within 5-20 days). By additional request we can use DHL, UPS or FEDex services. In this case price for shipping will be calculated individually.

 

We accept returns within 15 days after receiving goods.

MTL4575 TEMPERATURE CONVERTER THC or RTD input + Alarm

The MTLx575 converts a low-level dc signal from a temperature sensor mounted in a hazardous area into a 4/20mA current for driving a safearea load. Software selectable features include linearisation, ranging, monitoring, testing and tagging for all thermocouple types and 2-, 3- or 4-wire RTDs. (For thermocouple applications the HAZ-CJC plug on terminals 1–3 includes an integral CJC sensor). Configuration is carried out using a personal computer. A single alarm output is provided and may be configured for process alarm or to provide notice of early thermocouple failure.

SPECIFICATION

  • Number of channels One
  • Signal source
    • THC types J, K, T, E, R, S, B or N to BS 60584 and XK
    • mV input
    • RTDs 2/3/4-wire platinum to BS 60751
      • Pt 100, Pt 500, Pt 1000
      • Cu-50 & Cu-53
      • Ni 100/500/1000 DIN 43760
  • Location of signal source
    • Zone 0, IIC, T4-6 hazardous area
    • Division 1, Group A, hazardous location
  • Input signal range
    • –75 to +75mV, or 0 to 400Ω (0 to 1000Ω Pt & Ni sensors)
  • Input signal span
    • 3 to 150mV, or 10 to 400Ω (10 to 1000Ω Pt & Ni sensors)
  • RTD excitation current
    • 200µA nominal
  • Cold junction compensation
    • Automatic or selectable
  • Cold junction compensation error
    • ≤ 1.0°C
  • Common mode rejection
    • 120dB for 240V at 50Hz or 60Hz (500ms response)
  • Series mode rejection
    • 40dB for 50Hz or 60Hz
  • Calibration accuracy (at 20°C) (includes hysteresis, non-linearity and repeatability)
    • Inputs: (500ms response)
      • mV/THC: ± 15µV or ± 0.05% of input value (whichever is greater)
      • RTD: ± 80mΩ
      • Output: ± 11µA
  • Temperature drift (typical)
    • Inputs:
      • mV/THC: ± 0.003% of input value/°C
      • RTD: ± 7mΩ/°C
    • Output: ± 0.6µA/°C
  • Example of calibration accuracy and temperature drift (RTD input - 500ms response)
    • Span: 250Ω
    • Accuracy: ± (0.08/250 + 11/16000) x 100% = 0.1% of span
    • Temperature drift: ± (0.007/250 x 16000 + 0.6) µA/°C = ±1.0µA/°C
  • Safety drive on sensor failure
    • Upscale, downscale, or off

New, in factory box.

Typical delivery time:

  Economy shipping (Russian Post) Standard Shipping (EMS Express Post) Europe 14-30 days, in rare cases up to 60 days 7-20 days, in very rare cases up to 60 days United States 20-60 days, in rare cases up to 80 days 14-30 days, in rare cases up to 60 days Canada 14-30 days, in rare cases up to 60 days 7-30 days, in rare cases up to 60 days Asia, India, Africa 14-40 days, in rare cases up to 60 days 7-20 days, in very rare cases up to 60 days Australia and Oceania 14-40 days, in rare cases up to 60 days 10-25 days, in rare cases up to 60 days South and Central America 20-40 days, in rare cases up to 70 days 14-30 days, in rare cases up to 60 days Other countries 20-60 days, in rare cases up to 80 days 10-30 days, in rare cases up to 70 days