Schneider Electric Altivar inverter, frequency converter 5.5 kW 7.5 hp 380...500 V ATV312HU55N4
Typical delivery time:
Economy shipping (Russian Post)
Standard Shipping (EMS Express Post)
Europe
14-30 days, in rare cases up to 90 days
7-20 days, in
very rare cases up to 90 days
United States
20-60 days, in rare cases up to 90 days
14-30 days, in rare cases up to 90 days
Canada
14-30 days, in rare cases up to 90 days
7-30 days, in rare cases up to 90 days
Asia, India, Africa
14-40 days, in rare cases up to 90 days
7-20 days, in
very rare cases up to 90 days
Australia and Oceania
14-40 days, in rare cases up to 90 days
10-25 days, in rare cases up to 90 days
South and Central America
20-40 days, in rare cases up to 90 days
14-30 days, in rare cases up to 90 days
Other countries
20-60 days, in rare cases up to 90 days
10-30 days, in rare cases up to 90 days
Main
range of product
Altivar 312
product or component type
Variable speed drive
product destination
Asynchronous motors
product specific application
Simple machine
assembly style
With heat sink
component name
ATV312
motor power kW
5.5 kW
motor power hp
7.5 hp
[Us] rated supply voltage
380...500 V - 15...10 %
supply frequency
50...60 Hz - 5...5 %
network number of phases
3 phases
line current
21.9 A at 380 V, Isc = 22 kA
16.5 A at 500 V
EMC filter
Integrated
apparent power
15 kVA
maximum transient current
21.5 A for 60 s
power dissipation in W
232 W at nominal load
speed range
1…50
asynchronous motor control profile
Factory set : constant torque
Sensorless flux vector control with PWM type motor control signal
electrical connection
Al1, Al2, Al3, AOV, AOC, R1A, R1B, R1C, R2A, R2B, LI1...LI6 terminal 2.5 mm² AWG 14
L1, L2, L3, U, V, W, PA, PB, PA/+, PC/- terminal 16 mm² AWG 6
supply
Internal supply for logic inputs: 19...30 V 100 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (2.2 to 10 kOhm): 10...10.8 V 10 mA, protection type: overload and short-circuit protection
communication port protocol
Modbus
CANopen
IP degree of protection
IP20 on upper part without cover plate
IP21 on connection terminals
IP31 on upper part
IP41 on upper part
option card
Communication card for CANopen daisy chain
Communication card for DeviceNet
Communication card for Fipio
Communication card for Modbus TCP
Communication card for Profibus DP
Complementary
supply voltage limits
323…550 V
prospective line Isc
22 kA
continuous output current
14.3 A at 4 kHz
output frequency
0…500 kHz
nominal switching frequency
4 kHz
switching frequency
2...16 kHz adjustable
transient overtorque
170…200 % of nominal motor torque
braking torque
150 % during 60 s with braking resistor
100 % with braking resistor continuously
150 % without braking resistor
regulation loop
Frequency PI regulator
motor slip compensation
Automatic whatever the load
Adjustable
Suppressable
output voltage
19 V (state 0)
Positive logic (source) (LI1...LI6), < 5 V (state 0), > 11 V (state 1)
discrete output number
2
discrete output type
Configurable relay logic: (R1A, R1B, R1C) 1 NO + 1 NC - 100000 cycles
Configurable relay logic: (R2A, R2B) NC - 100000 cycles
minimum switching current
R1-R2 10 mA at 5 V DC
maximum switching current
R1-R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms
R1-R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms
R1-R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms
R1-R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms
discrete input number
6
discrete input type
(LI1...LI6) programmable at 24 V, 0…100 mA for PLC, impedance: 3500 Ohm
acceleration and deceleration ramps
Linear adjustable separately from 0.1 to 999.9 s
S, U or customized
braking to standstill
By DC injection
protection type
Input phase breaks: drive
Line supply overvoltage and undervoltage safety circuits: drive
Line supply phase loss safety function, for three phases supply: drive
Motor phase breaks: drive
Overcurrent between output phases and earth (on power up only): drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: motor
insulation resistance
>= 500 mOhm 500 V DC for 1 minute
local signalling
1 LED (red)drive voltage:
Four 7-segment display unitsCANopen bus status:
time constant
5 ms for reference change
frequency resolution
Analog input: 0.1...100 Hz
Display unit: 0.1 Hz
connector type
1 RJ45 for Modbus/CANopen
physical interface
RS485 multidrop serial link
transmission frame
RTU
transmission rate
10, 20, 50, 125, 250, 500 kbps or 1 Mbps for CANopen
4800, 9600 or 19200 bps for Modbus
number of addresses
1…127 for CANopen
1…247 for Modbus
number of drive
127 for CANopen
31 for Modbus
marking
CE
operating position
Vertical +/- 10 degree
outer dimension
442 x 239 x 192 mm
300 x 210 x 170 mm
232 x 180 x 170 mm
402 x 239 x 192 mm
height
232 mm
width
180 mm
depth
172 mm
net weight
6.5 kg