MTL4544S REPEATER POWER SUPPLY 2-channel, 4/20mA, HART®, 2- or 3- wire transmitters.

The MTLx544 provides fully-floating dc supplies for energising two conventional 2-wire or 3-wire 4/20mA or HART transmitters located in a hazardous area, and repeats the current in other circuits to drive two safe-area loads. For smart transmitters, the unit allows bi-directional transmission of digital communication signals superimposed on the 4/20mA loop current. Alternatively, the MTLx544S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.

SPECIFICATION

  • Number of channels Two
  • Location of transmitter Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location
  • Safe-area output
    • Signal range: 4 to 20mA
    • Under/over-range: 0 to 24mA
    • Safe-area load resistance (MTLx 544) @ 24mA: 0 to 360Ω @ 20mA: 0 to 450Ω
    • Safe-area load (MTLx544S) Current sink: 600Ω max. Maximum voltage source: 24V dc
    • Safe-area circuit output resistance: > 1MΩ
  • Safe-area circuit ripple < 50µA peak-to-peak
  • Hazardous-area input Signal range: 0 to 24mA (including over-range)
  • Transmitter voltage: 16.5V at 20mA
  • Transfer accuracy at 20°C Better than 15µA
  • Temperature drift < 0.8µA/°C
  • Response time Settles to within 10% of final value within 50µs
  • Communications supported HART (terminals 1 & 2 and 4 & 5 only)
  • LED indicator Green: power indication
  • Maximum current consumption (with 20mA signals) 96mA at 24V dc
  • Power dissipation within unit (with 20mA signals) MTLx544 1.4W @ 24V dc MTLx544S 1.9W @ 24V dc
  • Safety description (each channel) Terminals 2 to 1 and 3, and 5 to 4 and 6: Uo=28V Io=93mA Po=651mW Um = 253V rms or dc Terminals 1 to 3 and 4 to 6: Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected without further certification into any IS loop with an open-circuit voltage