EATON MTL4541S REPEATER POWER SUPPLY 4/20mA HART 2 3 wire transmitter MTL 4541 S
search
  • EATON MTL4541S REPEATER POWER SUPPLY 4/20mA HART 2 3 wire transmitter MTL 4541 S
  • EATON MTL4541S REPEATER POWER SUPPLY 4/20mA HART 2 3 wire transmitter MTL 4541 S

EATON MTL4541S REPEATER POWER SUPPLY 4/20mA HART 2 3 wire transmitter MTL 4541 S

$150.00
254580744864
Quantity
In Stock

 

We provide 6-month warranty for all used products. Before shipping all products carefully tested and packed in hard box with bubble wrap. If you pay with PayPal you can use buyer protection program.

 

For shipping we use EMS express post (delivery within 5-20 days). By additional request we can use DHL, UPS or FEDex services. In this case price for shipping will be calculated individually.

 

We accept returns within 15 days after receiving goods.

EATON MTL4541S REPEATER POWER SUPPLY 4/20mA, HART®, 2- or 3-wire transmitters.

The MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.

  • Number of channels
    • One
  • Location of transmitter
    • Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location
  • Safe-area output
    • Signal range: 4 to 20mA
    • Under/over-range: 0 to 24mA
    • Safe-area load resistance (MTLx541)
      • @ 24mA: 0 to 360Ω
      • @ 20mA: 0 to 450Ω
    • Safe-area load (MTLx541)
      • Current sink: 600Ω max.
      • Maximum voltage source: 24V dc
    • Safe-area circuit output resistance: > 1MΩ
  • Safe-area circuit ripple < 50µA peak-to-peak
  • Hazardous-area input
    • Signal range: 0 to 24mA (including over-range)
    • Transmitter voltage: 16.5V at 20mA
  • Transfer accuracy at 20°C Better than 15µA
  • Temperature drift < 0.8µA/°C
  • Response time Settles to within 10% of final value within 50µs
  • Communications supported HART (terminals 1 & 2 only)

New, in factory package.

Typical delivery time:

  Economy shipping (Russian Post) Standard Shipping (EMS Express Post) Europe 14-30 days, in rare cases up to 60 days 7-20 days, in very rare cases up to 60 days United States 20-60 days, in rare cases up to 80 days 14-30 days, in rare cases up to 60 days Canada 14-30 days, in rare cases up to 60 days 7-30 days, in rare cases up to 60 days Asia, India, Africa 14-40 days, in rare cases up to 60 days 7-20 days, in very rare cases up to 60 days Australia and Oceania 14-40 days, in rare cases up to 60 days 10-25 days, in rare cases up to 60 days South and Central America 20-40 days, in rare cases up to 70 days 14-30 days, in rare cases up to 60 days Other countries 20-60 days, in rare cases up to 80 days 10-30 days, in rare cases up to 70 days
5 Items

Data sheet

Brand
Eaton
MPN
MTL4541S
Model
4541S
Controller Platform
MTL