Phoenix Contact fuse modular terminal block UKK 5-HESI (5X20) 3007204 1pcs
We provide 6-month warranty for all used products. Before shipping all products carefully tested and packed in hard box with bubble wrap. If you pay with PayPal you can use buyer protection program.
For shipping we use EMS express post (delivery within 5-20 days). By additional request we can use DHL, UPS or FEDex services. In this case price for shipping will be calculated individually.
We accept returns within 15 days after receiving goods.
Fuse modular terminal block, fuse type: Glass / ceramics / ..., number of positions: 1, connection method: Screw connection, cross section: 0.2 mm²- 4 mm², AWG: 24 - 12, nominal current: 32 A, nom. voltage: 400 V, width: 8.2 mm, fuse type: G / 5 x 20, mounting type: NS 35/7,5, NS 35/15, NS 32, color: black.
New, in factory box.
Price for 1 (one) piece.
General Note For terminal marking, please use marking material with 8.2 mm pitch. For lever marking, please use flat marking material with 8.2 mm pitch. Number of levels 2 Number of connections 4 Nominal cross section 4 mm² Color black Insulating material PA Flammability rating according to UL 94 V0 Maximum power dissipation for nominal condition 1.02 W (the value is multiplied when connecting multiple levels) Fuse G / 5 x 20 Fuse type Glass / ceramics / ... Rated surge voltage 6 kV Degree of pollution 3 Overvoltage category III Insulating material group I Connection in acc. with standard IEC 60947-7-1 Maximum load current 32 A (Lower level) Nominal current IN 32 A Nominal voltage UN 400 V Connection in acc. with standard IEC 60947-7-3 Maximum load current (upper level) 6.3 A Nominal current IN (upper level) 6.3 A Nominal voltage UN 400 V Open side panel No Number of positions 1 Shock protection test specification DIN EN 50274 (VDE 0660-514):2002-11 Back of the hand protection guaranteed Finger protection guaranteed Relative insulation material temperature index (Elec., UL 746 B) 130 °C Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C Static insulating material application in cold -60 °C Behavior in fire for rail vehicles (DIN 5510-2) Test passed Flame test method (DIN EN 60695-11-10) V0 Oxygen index (DIN EN ISO 4589-2) >32 % NF F16-101, NF F10-102 Class I 2 NF F16-101, NF F10-102 Class F 2 Surface flammability NFPA 130 (ASTM E 162) passed Specific optical density of smoke NFPA 130 (ASTM E 662) passed Smoke gas toxicity NFPA 130 (SMP 800C) passed Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3 Dimensions Width 8.2 mm Length 86.5 mm Height NS 35/7,5 79 mm Height NS 35/15 86.5 mm Height NS 32 84 mm Connection data Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 4 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Conductor cross section flexible, with ferrule without plastic sleeve min. 0.25 mm² Conductor cross section flexible, with ferrule without plastic sleeve max. 4 mm² Conductor cross section flexible, with ferrule with plastic sleeve min. 0.25 mm² Conductor cross section flexible, with ferrule with plastic sleeve max. 4 mm² Cross section with insertion bridge, solid max. 4 mm² Cross section with insertion bridge, stranded max. 2.5 mm² 2 conductors with same cross section, solid min. 0.2 mm² 2 conductors with same cross section, solid max. 1.5 mm² 2 conductors with same cross section, stranded min. 0.2 mm² 2 conductors with same cross section, stranded max. 1.5 mm² 2 conductors with same cross section, stranded, ferrules without plastic sleeve, min. 0.25 mm² 2 conductors with same cross section, stranded, ferrules without plastic sleeve, max. 1.5 mm² 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min. 0.5 mm² 2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max. 1.5 mm² Cross section with insertion bridge, solid max. 4 mm² Cross section with insertion bridge, stranded max. 2.5 mm² Connection method Screw connection Stripping length 8 mm Screw thread M3 Tightening torque, min 0.5 Nm Tightening torque max 0.8 NmTypical delivery time:
Economy shipping (Russian Post) Standard Shipping (EMS Express Post) Europe 14-30 days, in rare cases up to 60 days 7-20 days, in very rare cases up to 60 days United States 20-60 days, in rare cases up to 80 days 14-30 days, in rare cases up to 60 days Canada 14-30 days, in rare cases up to 60 days 7-30 days, in rare cases up to 60 days Asia, India, Africa 14-40 days, in rare cases up to 60 days 7-20 days, in very rare cases up to 60 days Australia and Oceania 14-40 days, in rare cases up to 60 days 10-25 days, in rare cases up to 60 days South and Central America 20-40 days, in rare cases up to 70 days 14-30 days, in rare cases up to 60 days Other countries 20-60 days, in rare cases up to 80 days 10-30 days, in rare cases up to 70 daysData sheet
- Brand
- Phoenix Contact
- MPN
- 3007204